Case Study of Seismic Isolation Residential Building at Taipei Seismic Zone Two

This case study is an introduction of one seismic isolation residential building at Taipei Seismic Zone two.  The isolation layer is located in ground floor.  18 high-damping rubber bearing supports and 6 mega oil Dampers are used for the isolation system.
Except the introduction of the design and analysis of the isolation system, the drop-down elevator framing system, the damping system and the relevant design detail are also included.